ALL SILICONE FOLEY
BALLOON CATHETERS
|
|
All Silicone Foley Balloon Catheters are used
for routine drainage of the bladder or routine post-operative
drainage and irrigation of the bladder. This
catheter should be used only for urology.
|
|
|
|
|
|
Advantage
of Silicone Material
|
|
Non-reactive
with tissue
Non-adherence
to tissue permits easy removal
Silicone
material, compared to PVC, makes it more difficult
for protein to adhere to the
tube and tends to reduce bacterial growth on the
tube.
|
|
|
|
Features
of Products
|
|
X-Ray
opaque line (Standard Type: Green, UniBal Type:
Black)
Black
X-Ray opaque tip.
Transparent
tubing helps end user to make easy detection of
the problem of urine drainage.
|
|
|
|
UniBal
Type
|
|
|
|
|
|
Directions for Use
|
|
|
|
Insertion
|
|
- Lubricate the catheter using water soluble
jelly. - Insert catheter until catheter balloon
is properly positioned into bladder. - Fill sterile
water into balloon with syringe according to volume
indication on the catheter funnel.
|
|
- Do not over inflate.
|
|
- Check the urine flow from the drainage funnel
to ensure the function of catheter. - Connect
the urine drainage funnel to the connector of urine
bag
|
|
Removal
|
|
- Deflate the balloon completely by releasing
syringe plunger. Use only
gentle aspiration. - Remove the catheter
from patient.
|
|
|
|
2
Way Foley Balloon Catheter
|
Size (Fr)
|
Balloon Capacity
|
Length (mm)
|
|
Standard
|
UniBal
|
Integrated
|
Tiemann
|
|
1001-06
|
|
|
|
6
|
1.5ml
|
330 |
|
1001-08
|
1001UB-08
|
|
|
8
|
3ml
|
|
1001-10
|
1001UB-10
|
1001l-10
|
1011-10
|
10
|
|
1002-12
|
1002UB-12
|
1001l-12
|
1011-12
|
12
|
5ml
|
400
|
|
1002-14
|
1002UB-14
|
1001l-14
|
1011-14
|
14
|
|
1002-16
|
1002UB-16
|
1001l-16
|
1011-16
|
16
|
|
1002-18
|
1002UB-18
|
1001l-18
|
1011-18
|
18
|
|
1002-20
|
1002UB-20
|
1001l-20
|
1011-20
|
20
|
|
1002-22
|
1002UB-22
|
1001l-22
|
1011-22
|
22
|
|
1002-24
|
1002UB-24
|
1001l-24
|
1011-24
|
24
|
|
1002-26
|
1002UB-26
|
1001l-26
|
1011-26
|
26
|
|
|
|
|
Foley
Catheter Standard Type 30ml
Balloon
|
Size (Fr)
|
Balloon Capacity
|
Length (mm)
|
|
2Way
|
3Way
|
|
1004-14
|
1005-14
|
14
|
30ml
|
400 |
|
1004-16
|
1005-16
|
16
|
|
1004-18
|
1005-18
|
18
|
|
1004-20
|
1005-20
|
20
|
|
1004-22
|
1005-22
|
22
|
|
1004-24
|
1005-24
|
24
|
|
1004-26
|
1005-26
|
26
|
|
|
|
|
Do
not expose the product to high temperature, humid
air and ultraviolet ray during storage.
Sterility
guaranteed unless package has been opened or damaged.
Do not re-sterilize.
|